Peer-reviewed veterinary case report
Titanium mesh implantation--a method to stabilize the spine and protect the spinal cord following a multilevel laminectomy in the adult rat.
- Journal:
- Journal of neuroscience methods
- Year:
- 2005
- Authors:
- Nieto, Jaime H et al.
- Affiliation:
- Department of Neurology and Brain Research Institute · United States
- Species:
- rodent
Abstract
The development of clinically relevant larger spinal cord injury models is in part limited by the possibility of a widened or multilevel laminectomy causing a spinal cord injury from an unstable spine or from compression of the spinal cord by adjacent soft tissues. In the adult rat, we have developed a method to protect the spinal cord and stabilize the spinal column using a titanium mesh implant following a bilateral, multilevel lumbar laminectomy. For this purpose, bilateral and expanded L1-4 laminectomies were performed with or without the use of a titanium mesh to protect the spinal cord and stabilize the spine. Without titanium mesh protection, the rats developed a severe paraparesis or paraplegia, urinary retention, gross anatomical signs of cord compression, and motoneuron loss. In the titanium mesh treatment group, the rats typically maintained a normal gait and lower urinary tract function, normal gross anatomical features of the spinal cord, and normal motoneuron counts. We propose that the use of a titanium mesh implant may assist in the development of clinically relevant larger spinal cord injury and repair models.
Find similar cases for your pet
PetCaseFinder finds other peer-reviewed reports of pets with the same symptoms, plus a plain-English summary of what was tried across them.
Search related cases →Original publication: https://pubmed.ncbi.nlm.nih.gov/16024086/