PetCaseFinder

Peer-reviewed veterinary case report

Repeatability and reliability of kinetic and temporospatial gait parameters measured with a pressure-sensitive treadmill in healthy cats.

Journal:
Frontiers in veterinary science
Year:
2025
Authors:
Weißig, Dorothea M et al.
Affiliation:
LMU Small Animal Clinic · Germany
Species:
cat

Abstract

OBJECTIVES: Interest in feline kinetic gait variables has increased substantially. This study aimed to assess repeatability and intersession reliability of kinetic gait analysis in healthy cats using a pressure-sensitive treadmill. METHODS: Healthy client-owned cats (&#x202f;=&#x202f;9) and cats housed at the cattery of the Chair of Animal Nutrition and Dietetics (&#x202f;=&#x202f;5), without orthopedic abnormalities based on history, examination, and subjective gait analysis, were enrolled. Cats (mean body weight: 5.2&#x202f;&#xb1;&#x202f;0.9&#x202f;kg, age: 4.1&#x202f;&#xb1;&#x202f;1.7&#x202f;years) were acclimated to a pressure-sensitive treadmill system (FDM-T-CanidGait&#xae;, zebris Medical GmbH, Isny, Germany). Treadmill velocity was adjusted individually for comfortable walking. For data acquisition, cats were placed on the treadmill and repositioned if they jumped off (total duration: 10&#x202f;min, 5 &#xd7; 2&#x202f;min). The first five sequences with six valid gait cycles were selected. Data acquisition was repeated after 2&#x202f;weeks at the same speed. Average maximal pressure, loaded paw surface, step and stride length, step width, stance and swing phase percentages, hind reach, step-stride ratio, and symmetry indices were calculated. Repeatability was assessed with linear mixed-effects models and intersession reliability with intraclass correlation coefficients (ICCs). Reliability was categorized as excellent, good, moderate, or poor, with statistical significance set at a-value of < 0.05. RESULTS: Most parameters did not differ significantly between time points, except for the average maximal pressure of the left hindlimb (&#x202f;=&#x202f;0.037) and hind reach of both hindlimbs (&#x202f;&#x2264;&#x202f;0.001). ICCs demonstrated good to excellent reliability (0.885-0.988) for all variables, except for symmetry indices (moderate reliability; forelimbs: 0.547, hindlimbs: 0.676). CONCLUSION AND RELEVANCE: A pressure-sensitive treadmill provides repeatable feline gait measurements with good to excellent intersession reliability for most variables and moderate reliability for symmetry indices, offering a reference for future studies. Further studies involving larger cohorts are needed to confirm these results and support broader clinical application.

Find similar cases for your pet

PetCaseFinder finds other peer-reviewed reports of pets with the same symptoms, plus a plain-English summary of what was tried across them.

Search related cases →

Original publication: https://pubmed.ncbi.nlm.nih.gov/41479415/