PetCaseFinder

Peer-reviewed veterinary case report

Noninvasive Pressure-Volume Analysis by Three-Dimensional Echocardiography: A Novel Powerful Method for Evaluating Left Ventricular Function.

Journal:
Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
Year:
2025
Authors:
Hammersboen, Lars-Egil R et al.
Affiliation:
Institute for Surgical Research
Species:
dog

Abstract

BACKGROUND: Pressure-volume (PV) analysis is the gold standard for evaluating left ventricular (LV) function but is rarely used clinically due to its invasiveness. We validated a noninvasive method for PV analysis by three-dimensional (3D) echocardiography against invasive reference measurements and a novel index of LV efficiency against LV efficiency derived from metabolism by positron emission tomography-computed tomography (PET-CT). METHODS: In 22 canines, LV volume was measured invasively using piezoelectric crystals and LV pressure by micromanometer. Echocardiography and peak pressure were used to obtain 3D LV volume traces and LV pressure trace estimates. Stroke work, single-beat contractility indices, arterial elastance, and an index of LV efficiency were derived from echocardiography and compared with their invasively measured counterparts at baseline and different interventions. In 12 sheep, the LV efficiency index was compared with efficiency calculated as stroke work divided by total LV glucose metabolism from PET-CT. The sheep underwent 8 weeks of rapid dyssynchronous pacing to induce heart failure (HF). Recordings were performed during synchronous and dyssynchronous electrical activation, at baseline, and after 8 weeks of pacing-induced HF. RESULTS: In canines, there was a very good correlation and agreement between noninvasive and invasive measurements of LV stroke work (r = 0.98, P < .0001; difference 237 &#xb1; 212 mm Hg &#xd7; mL, mean &#xb1; SD). The noninvasive and invasive efficiency indices also showed very good agreement (r = 0.95, P < .0001; difference 0.4% &#xb1; 3.4%). The changes in LV function by the different interventions resulted in similar changes in the noninvasive and invasive PV indices (all P < .001). In sheep, the efficiency index showed similar decline compared to efficiency by PET-CT after induction of HF and after switching from synchronous to dyssynchronous electrical activation (r = 0.67, P < .001 for all interventions). CONCLUSIONS: Noninvasive PV analysis by three-dimensional echocardiography is feasible and accurate, making PV loop parameters for evaluating LV function accessible for clinical use. Further studies should explore the clinical utility of this method.

Find similar cases for your pet

PetCaseFinder finds other peer-reviewed reports of pets with the same symptoms, plus a plain-English summary of what was tried across them.

Search related cases →

Original publication: https://pubmed.ncbi.nlm.nih.gov/40412539/